14. OPTIONS AND AUXILIARY EQUIPMENT

14. OPTIONS AND AUXILIARY EQUIPMENT

WARNING

Before connecting any option or peripheral equipment, turn off the power and wait

for 15 minutes or more until the charge lamp turns off. Then, confirm that the
voltage between P and N is safe with a voltage tester and others. Otherwise, an
electric shock may occur. In addition, always confirm from the front of the servo
amplifier whether the charge lamp is off or not.

CAUTION

Use the specified auxiliary equipment and options. Unspecified ones may lead to a

fault or fire.


14.1 Options

14.1.1 Regenerative options

CAUTION

The specified combinations of regenerative options and servo amplifiers may only

be used. Otherwise, a fire may occur.


(1) Combination and regenerative power

The power values in the table are resistor-generated powers and not rated powers.

Regenerative power[W]

Servo amplifier

Built-in regenerative

resistor

MR-RB032

[40 ]

MR-RB12

[40 ]

MR-RB32

[40 ]

MR-RB30

[13 ]

(Note)

MR-RB50

[13 ]

MR-RB31

[6.7 ]

(Note)

MR-RB51

[6.7 ]

MR-J2S-10CP(1)

30

MR-J2S-20CP

(1)

10 30

100

MR-J2S-40CP

(1)

10 30

100

MR-J2S-60CP 10 30

100

MR-J2S-70CP 20 30

100

300

MR-J2S-100CP

20 30

100

300

MR-J2S-200CP

100

300

500

MR-J2S-350CP

100

300

500

MR-J2S-500CP

130

300

500

MR-J2S-700CP

170

300

500

Note. Always install a cooling fan.


(2) Selection of the regenerative option

(a) Simple selection method

In horizontal motion applications, select the regenerative option as described below.
When the servo motor is run without load in the regenerative mode from the running speed to a
stop, the permissible duty is as indicated in section 5.1 of the separately available Servo Motor
Instruction Manual.
For the servo motor with a load, the permissible duty changes according to the inertia moment of
the load and can be calculated by the following formula.

Permissible
duty

Permissible duty for servo motor with no load (value indication section 5.1 in Servo Motor Instruction Manual)

(m 1)

ratedspeed

running speed

[times/min]

2

where m

load inertia moment/servo motor inertia moment

From the permissible duty, find whether the regenerative option is required or not.
Permissible duty number of positioning times [times/min]
Select the regenerative option out of the combinations in (1) of this section.

Advertising