15 - 33

15. COMMUNICATION FUNCTIONS

15.12.12 Point table

(1) Data read

(a) Position data

Read the position data of the point table.
1) Transmission

Transmit command [4][0] and any of data No. [0][1] to [1][F] corresponding to the point table to
be read. Refer to section 15.11.1.

2) Reply

The slave station sends back the position data of the requested point table.

Hexadecimal data

Decimal point position
0: No decimal point
1: Lower first digit (usually not used)
2: Lower second digit
3: Lower third digit
4: Lower fourth digit
5: Lower fifth digit
6: Lower sixth digit

Display type
0: Used unchanged in hexadecimal
1: Conversion into decimal required
Position data write type
0: Valid after write
1: Valid when power is switched on again after write

0

0

(b) Speed data

Read the speed data of the point table.
1) Transmission

Transmit command [5][0] and any of data No. [0][1] to [0][F] corresponding to the point table to
be read. Refer to section 15.11.1.

2) Reply

The slave station sends back the speed data of the requested point table.

0

Hexadecimal data

Display type
0: Used unchanged in hexadecimal
1: Conversion into decimal required
Speed data write type
0: Valid after write
1: Valid when power is switched on again after write

0

0