Troubleshooting – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 236

Advertising
background image

11 - 5

11. TROUBLESHOOTING

Display Name

Definition

Cause

Action

1. Wrong setting of parameter No. 0 Set correctly.

2. Built-in regenerative resistor or

regenerative option is not

connected.

Connect correctly

3. High-duty operation or continuous

regenerative operation caused the

permissible regenerative power of

the regenerative option to be

exceeded.

Checking method

Call the status display and check
the regenerative load ratio.

1. Reduce the frequency of positioning.

2. Use the regenerative option of larger

capacity.

3. Reduce the load.

4. Power supply voltage is abnormal.

MR-J2S- CP:260VAC or more

MR-J2S- CP1:135VAC or more

Review power supply

Permissible

regenerative power

of the built-in

regenerative resistor

or regenerative

option is exceeded.

5. Built-in regenerative resistor or

regenerative option faulty.

Change servo amplifier or regenerative

option.

AL.30 Regenerative

error

Regenerative

transistor fault

6. Regenerative transistor faulty.

Checking method

1) The regenerative option has
overheated abnormally.
2) The alarm occurs even after
removal of the built-in
regenerative resistor or
regenerative option.

Change the servo amplifier.

1. Input command pulse frequency

exceeded the permissible
instantaneous speed frequency.

Set command pulses correctly.

2. Small acceleration/deceleration

time constant caused overshoot to
be large.

Increase acceleration/deceleration time
constant.

3. Servo system is instable to cause

overshoot.

1. Re-set servo gain to proper value.
2. If servo gain cannot be set to proper

value.
1) Reduce load inertia moment ratio; or
2) Reexamine acceleration/

deceleration time constant.

4. Electronic gear ratio is large

(parameters No. 4, 5)

Set correctly.

AL.31 Overspeed

Speed has exceeded
the instantaneous
permissible speed.

5. Encoder faulty.

Change the servo motor.

Advertising