Operation, Warning – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 132

Advertising
background image

4 - 41

4. OPERATION


(3) Structure

Component Description

Servo amplifier
Servo motor

Use standard models.

Battery MR-BAT

or

A6BAT

Encoder cable

Use a standard model.
When fabricating, refer to (2), section 14.1.4.


(4) Outline of absolute position detection data communication

For normal operation, as shown below, the encoder consists of a detector designed to detect a position
within one revolution and a cumulative revolution counter designed to detect the number of
revolutions.
The absolute position detection system always detects the absolute position of the machine and keeps
it battery-backed, independently of whether the general-purpose programming controller power is on
or off. Therefore, once the home position is defined at the time of machine installation, home position
return is not needed when power is switched on thereafter.
If a power failure or a fault occurs, restoration is easy.
Also, the absolute position data, which is battery-backed by the super capacitor in the encoder, can be
retained within the specified period (cumulative revolution counter value retaining time) if the cable is
unplugged or broken.

LSO
1XO

MR-BAT

Servo amplifier

Point table No. selection
(DI0 to DI3), etc.

I/O circuit

Position data, speed data
(current position read)

Home position return

data

EEP-ROM memory

Backup at
power off

Battery

Current position

LS

Speed detection

1X

Detection of position
within one revolution

Servo motor

Within one-revolution counter

High-speed serial
communication

S

p

eed c

ont

rol

P

o

si

tion

c

ont

ro

l

1 pulse/rev. Cumulative
revolution counter
Super capacitor


(5) Battery installation procedure

WARNING

Before installing a battery, turn off the main circuit power while keeping the control

circuit power on. Wait for 15 minutes or more until the charge lamp turns off. Then,
confirm that the voltage between P and N is safe with a voltage tester and others.
Otherwise, an electric shock may occur. In addition, always confirm from the front
of the servo amplifier whether the charge lamp is off or not.

POINT

The internal circuits of the servo amplifier may be damaged by static

electricity.
Always take the following precautions.

Ground human body and work bench.
Do not touch the conductive areas, such as connector pins and electrical

parts, directly by hand.

Advertising