7 input power supply circuit, 1 connection example, Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 74: Caution

Advertising
background image

3 - 25

3. SIGNALS AND WIRING


3.7 Input power supply circuit

CAUTION

Always connect a magnetic contactor (MC) between the main circuit power supply

and L

1

,

L

2

,

and L

3

of the servo amplifier, and configure the wiring to be able to shut

down the power supply on the side of the servo amplifier’s power supply. If a
magnetic contactor (MC) is not connected, continuous flow of a large current may
cause a fire when the servo amplifier malfunctions.

Use the trouble signal to switch power off. Otherwise, a regenerative transistor

fault or the like may overheat the regenerative resistor, causing a fire.


3.7.1 Connection example

Wire the power supply and main circuit as shown below so that the servo-on (SON) turns off as soon as
alarm occurrence is detected and power is shut off.
A circuit breaker (NFB) must be used with the input cables of the power supply.

(1) For 3-phase 200 to 230VAC power supply

RA

OFF

ON

MC

MC

SK

NFB

MC

L

1

L

2

L

3

L

11

L

21

EMG

SON

SG

VDD

COM

ALM

RA

3-phase
200 to 230 VAC

Forced stop

Servo-on

Trouble

Servo amplifier

Forced

stop