Mr configurator (servo configuration software) – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 168

Advertising
background image

6 - 7

6. MR Configurator (SERVO CONFIGURATION SOFTWARE)


(3) Point table data batch-read ( c) )

Click the “Read All” button to read and display all point table data from the servo amplifier.


(4) Point table data batch-write ( d) )

Click the “Write All” button to write all point table data to the servo amplifier.


(5) Point table data insertion ( e) )

Click the “Insert Row” button to insert one block of data into the position before the point table No.
chosen. The blocks after the chosen point table No. are shifted down one by one.


(6) Point table data deletion ( f) )

Click the “Delete Row” button to delete all data in the point table No. chosen. The blocks after the
chosen point table No. are shifted up one by one.


(7) Point table data change ( g) )

Click the data to be changed, enter a new value into the “Setting” input field, and press the enter key
or Enter Data button.


(8) Point table data file read

Used to read and display the point table data stored in the file. Use the “File” menu on the menu bar to
read.


(9) Point table data storage

Used to store all point table data being displayed on the window into the specified file. Use the “File”
menu on the menu bar to store.


(10) Point table data list print

Used to print all point table data being displayed on the window. Use the “File” menu on the menu
bar to print.


(11) Point table data list window closing ( h) )

Click the “Close” button to close the window.

Advertising