3 - 8

3. SIGNALS AND WIRING

Device name

Devices

symbol

Connector

pin No.

Functions/Applications

Temporary

stop/Restart

STP

Short STP-SG during automatic operation to make a temporary stop. Short STP-

SG again to make a restart.

Shorting the forward rotation start (ST1) or reverse rotation start (ST2) during a

temporary stop is ignored. Switching from automatic operation mode to manual

operation mode during a temporary stop clears the remaining moving distance.

During home position return and jog operation, the temporary stop/restart input is

ignored. Refer to section 4.2.6 (3).

Manual pulse

generator

multiplication 1

TP0

Used to select the multiplication factor of the manual pulse generator.

When it is not selected, the parameter No.1 setting is made valid.

(Note) Input signal

TP1 TP0

Manual pulse generator

multiplication factor

0

0

Parameter No.1 setting

0

1

1

time

1

0

10

times

1

1

100

times

Manual pulse

generator

multiplication 2

TP1

Note. 0: TP1/TP0-SG open

1: TP1/TP0-SG shorted

Gain switch

CDP

Connect CDP-SG to change the load inertia moment ratio into the parameter No.

64 setting and the gain values into the values multiplied by the parameter No. 65

to 67 settings.

Teach

TCH

Used when performing teaching. Shorting TCH-SG in the teaching setting mode

chooses this device and changes the position data of the point table No. to the

current position. (Refer to section 7.10.)