3 remedies for warnings, Troubleshooting, Caution – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 240

Advertising
background image

11 - 9

11. TROUBLESHOOTING

11.2.3 Remedies for warnings

CAUTION

If an absolute position counter warning (AL.E3) occurred, always make home

position setting again. Otherwise, misoperation may occur.

POINT

When any of the following alarms has occurred, do not resume operation by

switching power of the servo amplifier OFF/ON repeatedly. The servo
amplifier and servo motor may become faulty. If the power of the servo
amplifier is switched OFF/ON during the alarms, allow more than 30
minutes for cooling before resuming operation.

Excessive regenerative warning (AL.E0)
Overload warning 1 (AL.E1)

If AL.E6 occurs, the servo off status is established. If any other warning occurs, operation can be
continued but an alarm may take place or proper operation may not be performed. Use the optional MR

Configurator (servo configuration software) to refer to the cause of warning.

Display Name

Definition

Cause

Action

Positioning operation
was performed
without home
position return.

1. Positioning operation was performed

without home position return.

Perform home position return.

In incre

m

ental syste

m

Home position return
ended abnormally.

2. Home position return speed could not be

decreased to creep speed.

3. Limit switch was actuated during home

position return starting at other than

position beyond dog.

Review home position return
speed/creep speed/moving
distance after proximity dog.

Positioning operation
was performed
without home
position setting.

1. Positioning operation was performed

without home position setting.

Perform home position setting.

Home position setting
ended abnormally.

2. Home position setting speed could not be

decreased to creep speed.

3. Limit switch was actuated during home

position setting starting at other than

position beyond dog.

Review home position setting
speed/creep speed/moving
distance after proximity dog.

4. Voltage drop in encoder

(Battery disconnected.)

After leaving the alarm
occurring for a few minutes,
switch power off, then on again.
Always make home position
setting again.

5. Battery voltage low

AL.90 Home

position

return
incomplete

In

a

bs

ol

ut

e p

os

it

ion

det

ect

io

n s

ys

tem

Operation was
performed without
making home position
setting while an
absolute position
erase (AL.25) is being
occurred.

6. Battery cable or battery is faulty.

Change battery. Always make
home position setting again.

1. Battery cable is open.

Repair cable or changed.

AL.92 Open

battery

cable warning

Absolute position
detection system battery
voltage is low.

2. Battery voltage supplied from the servo

amplifier to the encoder fell to about

3.2V or less.

(Detected with the encoder)

Change battery.

1. Droop pulses remaining are greater

than the in-position range setting.

Remove the cause of droop pulse
occurrence

2. Command pulse entered after clearing

of droop pulses.

Do not enter command pulse
after clearing of droop pulses.

AL.96 Home

position

setting warning

Home position setting
could not be made.

3. Creep speed high.

Reduce creep speed.