Operation – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 97

Advertising
background image

4 - 6

4. OPERATION


(2) Point table

(a) Point table setting

Up to 15 point tables may be set. To use point table No.s 4 to 31, however, the point table No.
selection 3 (DI2), point table No. selection 4 (DI3) and point table No. selection 5 (DI4) should be
made valid in "I/O Devices" on the MR Configurator (servo configuration software).
Set the point tables using the MR Configurator (servo configuration software) or the servo
amplifier operation section.
The following table lists what to set. Refer to section 4.2.2, section 4.2.3 and section 4.2.4 for details
of the settings.

Name Description

Position data

Set the position data for movement.

Servo motor speed

Set the command speed of the servo motor for execution of positioning.

Acceleration time constant

Set the acceleration time constant.

Deceleration time constant

Set the deceleration time constant.

Dwell

Set the waiting time when performing automatic continuous operation.

Auxiliary function

Set when performing automatic continuous operation.

(b) Selection of point table

Using the input signal or communication function, select the point table No. with a command from
the command device (controller) such as a personal computer.
The following table lists the point table No. selected in response to the input signals/commands.
Note that when the input signals are used, the point tables used as standard are No.1 to 3. To use
No.4 to 31, the point table No. selection 3 (DI2), point table No. selection 4 (DI3) and point table
No. selection 5 (DI4) should be made valid in "I/O Devices" (Refer to chapter 6) on the MR
Configurator (servo configuration software).
When the communication function is used to select the point tables, refer to chapter 15 for details
of the command transmission method, etc.