4. OPERATION


4.6.4 Group designation

When using several servo amplifiers, command-driven parameter settings, etc. can be made on a group
basis.
You can set up to six groups, a to f. Set the group to each station using the communication command.

(1) Group setting example

CHARGE

MITSUBISHI

RS-422

CHARGE

MITSUBISHI

CHARGE

MITSUBISHI

CHARGE

MITSUBISHI

CHARGE

MITSUBISHI

CHARGE

MITSUBISHI

CHARGE

MITSUBISHI

CHARGE

MITSUBISHI

CHARGE

MITSUBISHI

CHARGE

MITSUBISHI

Group d

Group c

To CN3

Group a

Controller

Axis 1

(Station 0)

Axis 2

(Station 1)

Axis 3

(Station 2)

Axis 4

(Station 3)

Axis 5

(Station 4)

Group b

To CN3

To CN3

To CN3

To CN3

For cable connection diagram,
refer to section 15.1.1.

Axis 6

(Station 5)

To CN3

Axis 7

(Station 6)

To
CN3

Axis 8

(Station 7)

To CN3

Axis 9

(Station 8)

To
CN3

Axis 10

(Station 9)

To CN3

Servo amplifier station No.

Group setting

Station 0
Station 1
Station 2
Station 3

a

Station 4
Station 5

b

Station 6
Station 7

c

Station 8
Station 9

d

Advertising