3 status display list, Display and operation – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 185

Advertising
background image

7 - 4

7. DISPLAY AND OPERATION


7.2.3 Status display list

The following table lists the servo statuses that may be shown.

Display range

Status display Symbol

Unit

Description

Servo amplifier

display

MR-DP60

Current
position

PoS

10

STM

mm

The current position from the machine home position of 0 is
displayed.

99999 to

99999

999999 to

999999

Command
position

CPoS

10

STM

mm

The command position is displayed.

99999 to

99999

999999 to

999999

Command
remaining
distance

rn

10

STM

mm

The command remaining distance of the currently selected
point table is displayed.

99999 to

99999

999999 to

999999

Point table No.

PT

The point table No. being executed is displayed.

0 to 31

0 to 31

Cumulative
feedback
pulses

C pulse

Feedback pulses from the servo motor encoder are counted
and displayed.
When the value exceeds 9999999, it returns to zero.
Press the "SET" button to reset the display value to zero.

99999 to

99999

999999 to

999999

Servo motor
speed

r r/min

The servo motor speed is displayed.
" " is added to the speed of the servo motor rotating in the
CW rotation.

5400 to

5400

5400 to

5400

Droop pulses

E

pulse

The number of droop pulses in the deviation counter is
displayed.
" " is added to the droop pulses in the CW rotation.
The displayed number of pulses is not yet multiplied by the
electronic gear value.

99999 to

99999

999999 to

999999

Override F

%

The override setting is displayed.
100% is displayed when override is invalid.

0 to 200

0 to 200

Analog torque
limit voltage

u V

The voltage of the Analog torque limit (TLA) is displayed.

0.00 to 10.00 0.00 to 10.00

Regenerative
load ratio

L %

The ratio of regenerative power to permissible regenerative
power is displayed in %.

0 to 100

0 to 100

Effective load
ratio

J %

The continuous effective load torque is displayed.
The effective value in the past 15 seconds is displayed
relative to the rated torque of 100%.

0 to 300

0 to 300

Peak load ratio

b

%

The maximum torque generated during
acceleration/deceleration, etc.
The highest value in the past 15 seconds is displayed
relative to the rated torque of 100%.

0 to 300

0 to 300

Instantaneous
torque

T %

Torque that occurred instantaneously is displayed.
The value of the torque that occurred is displayed in real
time relative to the rate torque of 100%.

0 to 400

0 to 400

Within one-
revolution
position low

Cy1 pulse

Position within one revolution is displayed in encoder
pulses.
The value returns to 0 when it exceeds the maximum
number of pulses.
The value is incremented in the CCW direction of rotation.

0 to 99999

Within one-
revolution
position high

Cy2

100

pulse

The within one-revolution position is displayed in 100 pulse
increments of the encoder.
The value returns to 0 when it exceeds the maximum
number of pulses.
The value is incremented in the CCW direction of rotation.

0 to 1310

(Note)

0 to 131071

ABS counter

LS

rev

Travel value from the home position in the absolute position
detection systems is displayed in terms of the absolute
position detectors counter value.

32768 to

32767

32768 to

32767

Load inertia
moment ratio

dC times

The estimated ratio of the load inertia moment to the servo
motor shaft inertia moment is displayed.

0.0 to 300.0

0.0 to 300.0

Bus voltage

Pn

V

The voltage (across P-N) of the main circuit converter is
displayed.

0 to 450

0 to 450

Note. The MR-DP60 can display the status without dividing it into the high and low orders. The unit is [pulse].

Advertising