11. TROUBLESHOOTING

Display Name

Definition

Cause

Action

1. Servo amplifier fault caused the

parameter setting to be rewritten.

Change the servo amplifier.

2. Regenerative option not used with

servo amplifier was selected in
parameter No.0.

Set parameter No.0 correctly.

3. Value outside setting range has

been set in some parameter.

Set the parameter correctly.

4. Value outside setting range has

been set in electronic gear.

Set parameters No. 4, 5 correctly.

5. Opposite sign has been set in

software limit increasing side
(parameters No. 46, 47). Similarly,
opposite sign has been set in
software limit decreasing side
(parameters No. 48, 49).

Set parameters No. 46 to 49 correctly.

6. Opposite sign has been set in

position range output address
increasing side (parameters No. 50,
51). Similarly, opposite sign has
been set in position range output
address decreasing side
(parameters No. 52, 53).

Set parameters No. 50 to 53 correctly.

AL.37 Parameter

error

Parameter setting is
wrong.

7. The number of write times to EEP-

ROM exceeded 100,000 due to
parameter write, program write,
etc.

Change the servo amplifier.

1. Servo amplifier faulty.

Change the servo amplifier.

2. The power supply was turned on

and off continuously by overloaded
status.

The drive method is reviewed.

AL.45 Main

circuit

device overheat

Main circuit device
overheat

3. Air cooling fan of servo amplifier

stops.

1. Exchange the cooling fan or the servo

amplifier.

2. Reduce ambient temperature.

1. Ambient temperature of servo

motor is over 40 (104 ).

Review environment so that ambient
temperature is 0 to 40 (32 to 104 ).

2. Servo motor is overloaded.

1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger

output.

AL.46 Servo

motor

overheat

Servo motor
temperature rise
actuated the
thermal sensor.

3. Thermal sensor in encoder is faulty. Change servo motor.
1. Servo amplifier is used in excess of

its continuous output current.

1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger

output.

2. Servo system is instable and

hunting.

1. Repeat acceleration/

deceleration to execute auto tuning.

2. Change auto tuning response setting.
3. Set auto tuning to OFF and make gain

adjustment manually.

3. Machine struck something.

1. Review operation pattern.
2. Install limit switches.

4. Wrong connection of servo motor.

Servo amplifier's output terminals
U, V, W do not match servo motor's
input terminals U, V, W.

Connect correctly.

AL.50 Overload

1

Load

exceeded

overload protection
characteristic of
servo amplifier.

5. Encoder faulty.

Checking method

When the servo motor shaft is
rotated with the servo off, the

cumulative feedback pulses do

not vary in proportion to the

rotary angle of the shaft but the

indication skips or returns midway.

Change the servo motor.