(1) Setting

Set the input signal and parameters as follows according to the purpose of use. In this case, the point
table No. selection 1 to 5 (DI0 to DI4) are invalid.

Item Setting

method Description

Manual operation mode selection

Automatic/manual selection (MD0)

Open MD0-SG (OFF).

Manual pulse generator
multiplication

Parameter No.1

Set the multiplication ratio of servo
motor rotation to the pulses generated by
the manual pulse generator.
For more information, refer to (3) of this
section.

Servo motor rotation direction

Parameter No.1

Refer to (2) of this section.


(2) Servo motor rotation direction

Servo motor rotation direction

Parameter No. 1 setting

Manual pulse generator: forward rotation

Manual pulse generator: reverse rotation

0

CCW rotation

CW rotation

1

CW rotation

CCW rotation

Forward rotation

CCW

CW

(3) Manual pulse generator multiplication

(a) Using the parameter for setting

Use parameter No.1 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.

Parameter No. 1 setting

Multiplication ratio of servo motor rotation to manual

pulse generator rotation

Moving distance

0

1

time

1[ m]

1

10

times

10[ m]

2

100

times

100[ m]