Operation – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 127

Advertising
background image

4 - 36

4. OPERATION


4.4.8 Count type front end reference home position return

POINT

This home position return method depends on the timing of reading

Proximity dog (DOG) that has detected the front end of a proximity dog.

Hence, if a home position return is made at the home position return speed

of 100r/min, an error of 200 pulses will occur in the home position. The

error of the home position is larger as the home position return speed is

higher.

The position where the axis, which had started decelerating at the front end of a proximity dog, has

moved the after-proximity dog moving distance and home position shift distance is defined as a home

position. A home position return that does not depend on the Z-phase signal can be made. The home

position may change if the home position return speed varies.

(1) Signals, parameters

Set the input signals and parameters as indicated below.

Item Device/Parameter

used

Description

Automatic/manual selection (MD0) Short (turn on) MD0-SG.
Point table No. selection 1 (DI0)

Open (turn off) DI0-SG.

Manual home position return mode
selection

Point table No. selection 2 (DI1)

Open (turn off) DI1-SG.

Count type dog front end reference
home position return

Parameter No.8

6: Select the count type dog front end reference.

Home position return direction

Parameter No.8

Refer to section 4.4.1 (2) and select the home position return
direction.

Dog input polarity

Parameter No.8

Refer to section 4.4.1 (2) and select the dog input polarity.

Home position return speed

Parameter No.9

Set the speed till the dog is detected.

Creep speed

Parameter No.10

Set the speed after the dog is detected.

Home position shift distance

Parameter No.11

Set when the home position is moved from where the axis has passed
the proximity dog rear end.

Moving distance after proximity dog

Parameter No.43

Set the moving distance after the axis has passed the proximity dog
rear end.

Home position return acceleration/
deceleration time constants

Point table No.1

Use the acceleration/deceleration time constant of point table No. 1.

Home position return position data

Parameter No.42

Use to set the current position on completion of home position return.

(2) Timing chart

ON

OFF
ON

OFF
ON

OFF

ON

OFF
ON

OFF

ON

OFF

Movement finish (MEND)

Rough match (CPO)

Home position return

completion (ZP)

Servo motor speed

Proximity dog (DOG)

Forward rotation

start (ST1)

5ms or more

3ms or less

Proximity dog (DOG)

Creep speed

Moving distance after proximity dog

Home position shift distance

Home position return speed

Automatic/manual

selection (MD0)

Home position address

Parameter No. 42

Reverse rotation

start (ST2)

ON

OFF

The parameter No.42 (home position return position data) setting value is the positioning address

after the home position return is completed.

Advertising