7. DISPLAY AND OPERATION


7.4.2 Alarm mode list

Name Display

Description

Indicates no occurrence of an alarm.

Current alarm

Indicates the occurrence of overvoltage (AL.33).
Flickers at occurrence of the alarm.

Indicates that the last alarm is overload 1 (AL.50).

Indicates that the second alarm in the past is overvoltage
(AL.33).

Indicates that the third alarm in the past is undervoltage
(AL.10).

Indicates that the fourth alarm in the past is overspeed (AL.31).

Indicates that there is no fifth alarm in the past.

Alarm history

Indicates that there is no sixth alarm in the past.

Indicates no occurrence of parameter error.

Indicates that the data of parameter No. 1 is faulty.

Parameter error No.

Displayed when any of the set point table values exceeds the
setting range.
The display given on the left indicates an error in the position
data of point table No. 1.
P: Position data, d: Servo motor speed, A: Acceleration time
constant, b: Deceleration time constant, n: Dwell,
H: Auxiliary function