11. TROUBLESHOOTING


11.2 When alarm or warning has occurred

POINT

Configure up a circuit which will detect the trouble (ALM) signal and turn

off the servo-on (SON) signal at occurrence of an alarm.


11.2.1 Alarms and warning list

When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or
warning has occurred, refer to section 11.2.2 or 11.2.3 and take the appropriate action.
Set "1 " in parameter No. 59 to output the alarm code in ON/OFF status across the corresponding
pin and SG. Warnings (AL.90 to AL.E9) have no alarm codes. Any alarm code is output at occurrence of
the corresponding alarm. In the normal status, the signals available before alarm code setting (CN1B-19,
CN1A-18, CN1A-19) are output.
After its cause has been removed, the alarm can be deactivated in any of the methods marked in the
alarm deactivation column.

(Note 2) Alarm code

Alarm deactivation

Display

CN1B-19

pin

CN1A-18

pin

CN1A-19

pin

Name

Power

OFF ON

Press

"SET" on

current

alarm

screen.

Alarm

reset

(RES)

signal

AL.10 0

1

0

Undervoltage

AL.12 0

0

0

Memory

error

1

AL.13 0

0

0

Clock

error

AL.15 0

0

0

Memory

error

2

AL.16 1

1

0

Encoder

error

1

AL.17 0

0

0

Board

error

AL.19 0

0

0

Memory

error

3

AL.1A 1

1

0

Motor

combination

error

AL.20 1

1

0

Encoder

error

2

AL.24

1

0

0

Main circuit error

AL.25 1

1

0

Absolute

position

erase

AL.30 0

0

1

Regenerative

error

(Note 1)

(Note 1)

(Note 1)

AL.31 1

0

1

Overspeed

AL.32 1

0

0

Overcurrent

AL.33 0

0

1

Overvoltage

AL.35

1

0

1

Command pulse frequency error

AL.37 0

0

0

Parameter

error

AL.45

0

1

1

Main circuit device overheat

(Note 1)

(Note 1)

(Note 1)

AL.46

0

1

1

Servo motor overheat

(Note 1)

(Note 1)

(Note 1)

AL.50 0

1

1

Overload

1

(Note 1)

(Note 1)

(Note 1)

AL.51 0

1

1

Overload

2

(Note 1)

(Note 1)

(Note 1)

AL.52 1

0

1

Error

excessive

AL.61 1

0

1

Home

operation

alarm

AL.8A

0

0

0

Serial communication time-out error

AL.8E

0

0

0

Serial communication error

Alar

m

s

88888 0

0

0

Watchdog

AL.90

Home position return incomplete

AL.92

Open battery cable warning

AL.96

Home position setting warning

AL.98 Software

limit

warning

AL.9F Battery

warning

AL.E0 Excessive

regenerative

warning

AL.E1 Overload

warning

AL.E3

Absolute position counter warning

AL.E6

Servo forced stop warning

Wa

rni

ngs

AL.E9

Main circuit off warning

Removing the cause of occurrence
deactivates the alarm
automatically.

Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.

2. 0: Pin-SG off (open)
1: Pin-SG on (short)