3 power regeneration converter, Options and auxiliary equipment – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 272

Advertising
background image

14 - 15

14. OPTIONS AND AUXILIARY EQUIPMENT

(b) FR-BR resistor unit

[Unit: mm]

2 C

Control circuit
terminal

Main circuit
terminal

W1 1

Approx. 35

Approx. 35

C

C

W 5

(Note)

(Note)

Note. Ventilation ports are provided on both sides and the top. The bottom is open.

Resistor

unit

W W1 H H1 H2 H3 D D1 C

Approximate

mass

[kg]([Ib])

FR-BR-15K 170 100 450 410 20 432 220 3.2 6

15(33.1)

FR-BR-30K 340 270 600 560 20 582 220 4 10 30(66.1)


14.1.3 Power regeneration converter

When using the power regeneration converter, set "01

" in parameter No.0.

(1) Selection

The converters can continuously return 75% of the nominal regenerative power. They are applied to
the servo amplifiers of the MR-J2S-500CP and MR-J2S-700CP.

Power

regeneration

converter

Nominal

regenerative

power (kW)

Servo amplifier

FR-RC15 15
FR-RC30 30

MR-J2S-500CP
MR-J2S-700CP

0

50

75

100

150

500

300

200

100

50

30
20

Cont

in

uo

us

ene

rg

iza

tion t

im

e [

sec

]

Nominal regenerative power (%)

Advertising