(1) Specifications

Item Specifications

Voltage

4.5 to 13.2VDC

Power supply

Current consumption

60mA max.

Interface

Output current max. 20mA for open collector output

Pulse signal form

A-phase and B-phase signals with 90°phase difference

Pulse resolution

100pulse / rev

Max. speed

Instantaneous max. 600r/min, ordinary 200r/min

Operating temperature range

10 to 60 (14 to 140 )

Storage temperature range

30 to 80 ( 22 to 176 )


(2) Connection example

Use an external power supply to supply power to the manual pulse generator.

Manual pulse generator
MR-HDP01

SV

A

OV

B

External
power
supply

+5

GND

VDD

OPC

PP

SG
NP

SD

3

11

3

10

2

Plate

Servo amplifier

CN1B

CN1A

(3) Terminal arrangement

Signal name

Description

5 to 12V

Power input

0V

Power and signal common

A

A-phase pulse output

+5 to
12V 0V A B

B

B-phase pulse output