14. OPTIONS AND AUXILIARY EQUIPMENT

Dimensions [mm (in) ]

Servo amplifier

Model

W W1 H D D1 C

Mounting

screw size

Terminal

screw size

Mass

[kg (lb)]

MR-J2S-10CP(1)/20CP FR-BAL-0.4K

135 (5.31) 120 (4.72) 115 (4.53) 59 (2.32)

45

(1.77

)

7.5 (0.29)

M4

M3.5

2.0 (4.4)

MR-J2S-40CP/20CP1 FR-BAL-0.75K 135 (5.31) 120 (4.72) 115 (4.53) 69 (2.72)

57

(2.24

)

7.5 (0.29)

M4

M3.5

2.8 (6.17)

MR-J2S-60CP/ 70CP/
40CP1

FR-BAL-1.5K

160 (6.30) 145 (5.71) 140 (5.51) 71 (2.79)

55

(2.17

)

7.5 (0.29)

M4

M3.5

3.7 (8.16)

MR-J2S-100CP

FR-BAL-2.2K

160 (6.30) 145 (5.71) 140 (5.51) 91 (3.58)

75

(2.95

)

7.5 (0.29)

M4

M3.5

5.6 (12.35)

MR-J2S-200CP

FR-BAL-3.7K

220 (8.66) 200 (7.87) 192 (7.56) 90 (3.54)

70

(2.76

)

10 (0.39)

M5

M4

8.5 (18.74)

MR-J2S-350CP

FR-BAL-7.5K

220 (8.66) 200 (7.87) 194 (7.64) 120 (4.72)

100

(3.94

)

10 (0.39)

M5

M5

14.5 (32.0)

MR-J2S-500CP FR-BAL-11K

280

(11.02) 255 (10.04) 220 (8.66) 135 (5.31)

100

(3.94

)

12.5 (0.49)

M6 M6

19

(41.9)

MR-J2S-700CP FR-BAL-15K

295

(11.61) 270 (10.62) 275 (10.83) 133 (5.24)

110

(4.33

)

12.5 (0.49)

M6 M6

27

(59.5)


14.2.4 Relays

The following relays should be used with the interfaces.

Interface Selection

example

Relay used for input signals (interface DI-1) signals

To prevent defective contacts , use a relay for small signal
(twin contacts).
(Ex.) Omron : type G2A , MY

Relay used for digital output signals (interface DO-1)

Small relay with 12VDC or 24VDC of 40mA or less
(Ex.) Omron : type MY


14.2.5 Surge absorbers

A surge absorber is required for the electromagnetic brake. Use the following surge absorber or equivalent.

Insulate the wiring as shown in the diagram.

Maximum rating

Permissible circuit

voltage

Surge

immunity

Energy

immunity

Rated
power

Maximum

limit voltage

Static

capacity

(reference

value)

Varistor voltage

rating (range) V1mA

AC[Vma] DC[V]

[A]

[J]

[W] [A] [V]

[pF]

[V]

140 180

(Note)

500/time

5 0.4

25

360

300

220

(198 to 242)

Note. 1 time 8 20 s

(Example) ERZV10D221 (Matsushita Electric Industry)
TNR-10V221K (Nippon chemi-con)
Outline drawing [mm] ( [in] ) (ERZ-C10DK221)

13.5 (0.53)

16

.5

(0

.6

5)

3.

0

(0

.1

2)

or

le

ss

30

.0

(

1.

18

)

or

m

or

e

Crimping terminal
for M4 screw

Vinyl tube

4.7 1.0 (0.19 0.04)

0.8 (0.03)