14 - 47

14. OPTIONS AND AUXILIARY EQUIPMENT


14.2.8 EMC filter

For compliance with the EMC Directive of the EN Standard, it is recommended to use the following filter.
Some EMC filters are large in leakage current.

(1) Combination with the servo amplifier

Recommended filter

Servo amplifier

Model

Leakage current [mA]

Mass [kg]([lb])

MR-J2S-10CP to MR-J2S-100CP
MR-J2S-10CP1 to MR-J2S-40CP1

SF1252 38

0.75

(1.65)

MR-J2S-200CP MR-J2S-350CP SF1253

57

1.37

(1.65)

MR-J2S-500CP

(Note)

HF-3040A-TM 1.5 5.5

(12.13)

MR-J2S-700CP

(Note)

HF-3050A-TM

1.5

6.7 (14.77)

Note. Soshin Electric. A surge protector is separately required to use any of these EMC filters. (Refer to the EMC Installation

Guidelines.)


(2) Connection example

L

1

L

2

L

3

L

11

L

21

L

1

L

2

L

3

L

1

L

2

L

3

LINE

LOAD

(Note 2)

NFB

MC

(Note 1)

Power

supply

EMC filter

(SF1252, SF1253)

Servo amplifier

L

1

L

2

L

3

L

11

L

21

Servo amplifier

1

2

3

4

5

6

E

MC

Surge protector 1
(RAV-781BYZ-2)
(OKAYA Electric Industries

Co., Ltd.)

Surge protector 2
(RAV-781BXZ-4)

(OKAYA Electric Industries Co., Ltd.)

NFB

(Note 1)

Power

supply

1

2

3

1 2 3

EMC filter

(SOSHIN Electric Co., Ltd)

Note 1. For 1-phase 230VAC power supply, connect the power supply to L

1

,L

2

and leave L

3

open.

There is no L

3

for 1-phase 100 to 120VAC power supply. Refer to section 1.2 for the power supply specification.

2. Connect when the power supply has earth.