1. FUNCTIONS AND CONFIGURATION

Function Description

Reference

Analog monitor

The servo status is output in terms of voltage in real time.

Section 5.2.4

Alarm history

By using the MR Configurator (servo configuration software), the
current alarm and five past alarm numbers are stored and
displayed.

Section 6.8

I/O signal selection (Device setting)

By using the MR Configurator (servo configuration software), any
devices can be assigned to 9 input, 5 output and 1 I/O pins.

Section 6.6

Torque limit

Servo motor-torque is limited.
Parameter 2 limit value
Analog input 1 limit value

Section 3.4.4

Override (speed limit)

The servo motor speed is limited by analog input.
The ratio of override to the set speed can be changed between 0 to
200%.

Section 3.4.3

Status display

The servo status is displayed.

Section 7.2

Test operation mode

Jog operation, positioning operation, motor-less operation, DO
forced output, 1-step feed

Section 6.7

Limit switch

The servo motor travel region can be limited using the forward
rotation stroke end (LSP)/reverse rotation stroke end (LSN).

Section 5.2.5

Software limit

The travel region is limited using parameters in terms of address.
The function similar to that of a limit switch is limited by
parameter.

Section 5.2.8


1.4 Model code definition

(1) Rating plate

POWER

MITSUBISHI

AC SERVO

MADE IN JAPAN

MODEL

MR-J2S-60CP

MITSUBISHI ELECTRIC CORPORATION

600W

3.2A 3PH 1PH200-230V 50Hz

170V 0-360Hz 3.6A

POWER :
INPUT :

OUTPUT :
SERIAL :

AC SERVO

A5

PASSED

Model
Capacity

Applicable power supply

Rated output current

Serial number

3PH 1PH200-230V 60Hz

5.5A 1PH 230V 50/60Hz

TC3 AAAAG52