7 input devices on/off (test operation), Communication functions – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 333

Advertising
background image

15 - 26

15. COMMUNICATION FUNCTIONS


15.12.7 Input devices ON/OFF (test operation)

Each input devices can be turned on/off for test operation. when the device to be switched off exists in the
external input signal, also switch off that input signal.
Send command [9] [2], data No. [0] [0] and data.

Command

Data No.

Set data

[9][2] [0][0]

See

below

b31

b0

0: OFF

1: ON

b1

Command of each bit is transmitted to the slave
station as hexadecimal data.

bit Signal

name

bit Signal

name bit

Signal

name

0 Servo-on (SON)

12 Reverse rotation start (ST2)

24 Temporary stop/restart (STP)

1 Forward rotation stroke limit (LSP) 13

2 Reverse rotation stroke limit (LSN) 14

25

Manual pulse generator
multiplication 1 (TP0)

3 External torque limit selection (TL) 15

4 Internal torque limit selection (TL2) 16 Forced stop (EMG)

26

Manual pulse generator
multiplication 2 (TP1)

5 Proportion control selection (PC)

17 Automatic/manual selection (MD0)

27 Gain switch (CDP)

6 Reset (RES)

18 Proximity dog (DOG)

28

7

19 Point table No. selection 1 (DI0)

29 Point table No. selection 5 (DI4)

8

20 Point table No. selection 2 (DI1)

30 Teach (TCH)

9

21 Point table No. selection 3 (DI2)

31

10

22 Point table No. selection 4 (DI3)

11 Forward rotation start (ST1)

23 Override selection (OVR)

Advertising