3. SIGNALS AND WIRING


3.3.2 Signal (devices) explanations

(1) I/O devices

POINT

The devices not indicated in the Connector Pin No. field of the I/O devices

can be assigned to the connector CN1A/CN1B using the MR Configurator
(servo configuration software).

(a) Pins whose devices can be changed

Refer to section 3.6.2 for the I/O interfaces (symbols in the I/O Division field in the table) of the
corresponding connector pins.

Pin type

Connector pin No.

I/O division

Device in initial status

CN1B-5

Point table No. selection 1 (DI0)

CN1B-14

Point table No. selection 2 (DI1)

CN1A-8 Proximity

dog

(DOG)

CN1B-15 Servo-on

(SON)

CN1B-16

Forward rotation stroke end (LSP)

CN1B-17

Reverse rotation stroke end (LSN)

CN1B-7

Automatic/manual selection (MD0)

CN1B-8

Forward rotation start (ST1)

Input-only pins

CN1B-9

DI-1

Reverse rotation start (ST2)

I/O pin

CN1A-19

DI-1 or DO-1

No device has been assigned in the initial
status. You can assign an I/O device using
the MR Configurator (servo configuration
software).

CN1B-4 Rough

match

(CPO)

CN1B-6 Movement

finish

(MEND)

CN1B-18 Trouble

(ALM)

CN1B-19 Ready

(RD)

Output-only pins

CN1A-18

DO-1

Home position return completion(ZP)

(b) Input devices

Device name

Devices

symbol

Connector

pin No.

Functions/Applications

Forced stop

EMG

When EMG-SG are opened, the servo amplifier is placed in the forced stop status,
the servo switches off, and the dynamic brake is operated to bring the servo motor
to a sudden stop.
Short EMG-SG in the forced stop status to cancel the forced stop status.

Servo-on SON

CN1B

15

Connect SON-SG to switch on the base circuit and make the servo amplifier ready
to operate (servo-on).
Disconnect SON-SG to shut off the base circuit and coast the servo motor (servo-
off) .

Reset

RES

Disconnect RES-SG for more than 50ms to reset the alarm.
Some alarms cannot be deactivated by the reset signal. Refer to section 11.2.1
If RES-SG are shorted in no alarm status, the base circuit is not shut off.
Set " 1 " in parameter No. 55 to shut off the base circuit.
Since this device is not designed for stopping. Do not switch it on during operation.