3 override, Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- CP User Manual

Page 65

Advertising
background image

3 - 16

3. SIGNALS AND WIRING


3.4.3 Override

POINT

When using the override (VC), make the override selection (OVR) device

available.


The override (VC) may be used to change the servo motor speed. The following table lists the signals and
parameter related to the override.

Item Name

Remarks

Analog input signal

Override (VC)

Contact input signal

Override selection (OVR)

MR Configurator (servo configuration software)
setting required.

Parameter

No.25 override offset

999 to 999mV


(1) Override (VC)

By applying a voltage ( 10 to 10V) to the override (VC) terminal, change values can be set from
outside consecutively. The following graph shows the relationship between the input voltage and the
ratio of actual speed to preset speed.

Override selection (OVR)

OVR
SG

VC
LG

Servo amplifier

Override (VC)

Override (VC) application voltage

Rat

io o

f ac

tual

s

pee

d t

o

preset

speed

10

10

200

[%]

0

[V]

0

100

SD

10 to 10V

(2) Override selection (OVR)

Used to make the override (VC) valid or invalid.

Servo amplifier

Override selection
(OVR)

O

verri

de

Override (VC)
10 to 10V

Motor

Using the override selection (OVR), choose a change value as follows.

(Note)

External input signal

OVR

Speed change value

0 No

change

1

Override (VC) setting is made valid.

Note. 0 : Off (open) across OVR-SG

1 : On (shorted) across OVR-SG


(3) Override offset (parameter No.25)

Using parameter No.25, the offset voltage can be set relative to the input voltage for the override (VC).
The setting is between 999 to 999mV.