DrvGII PC Utility

8

(12) The displayed waveform can be reshaped using “Display position selection” and “Vertical axis range

selection” in the "Oscilloscope" dialog box.
When "Auto" is clicked at this time, the "Display position selection" value is changed to "5," and the
"Vertical axis range selection" value is changed automatically to a value that enables to display the entire
waveform as much as possible without cutting any part of the waveform.

(13) When "Condition and display" under "Data save" is clicked, the status set in the

"SetCondition/ELogStart" dialog box as well as the values set by "Display position selection" and "Vertical
axis range selection" can be saved by assigning a file name.
In addition, when "Graph" under "Data save" is clicked, the waveform currently being displayed, the status
set in the "SetCondition/ELogStart" dialog box, and the values set by "Display position selection" and
"Vertical axis range selection" can be saved by assigning a file name.

∗ The status set in the "SetCondition/ELogStart" dialog box as well as the values set by "Display position

selection" and "Vertical axis range selection" are automatically saved in the "oscscope.cnd" file when the
"Oscilloscope" dialog box is closed. When the dialog box is opened next time, it displays the previous setting
values.

(14) When "Condition and display" under "Data load" is clicked, the setting status of the

"SetCondition/ELogStart" dialog box as well as the values set by "Display position selection" and "Vertical
axis range selection" are loaded from files, and then displayed. The waveform is cleared at this time and all
values are set to 0.
In addition, when "Graph" under "Data save" is clicked, the waveform data, the setting status in the
"SetCondition/ELogStart" dialog box, and the values set by "Display position selection" and "Vertical axis
range selection" are loaded from files, and then a waveform is displayed.

Note: If the trigger condition that has been set cannot be established and "Start acquisition" cannot be activated,

click "Log stop" and set a new trigger condition again.

∗ The simplified terminal function is provided in the "Oscilloscope" dialog box. Use this function in order to

change parameter values or to start an operation.