Parameter No.

Parameter name

Minimum value

Maximum value

Initial value

Unit

Possible to change

152

First order delay compensator setting

0

3

0

None

Always

153

Notch filter: Frequency 1 selection

50

1500

1500

Hz

Always

154

Notch filter: Frequency 2 selection

50

1500

1500

Hz

Always

155

Load inertial/load mass

0

200000

0

1/1000kgm

2

or

1/1000kg

Always

201

Selection of English/Japanese display

0

1

0

None

While in machine
setting mode

202

Coordinate (+) direction setting

0

1

1

None

While in machine
setting mode

203

Using position current value filter

0

1

Motor dependent

None

While in machine
setting mode

204

Command pulse type

0

2

2

None

While in machine
setting mode

205

Monitor pulse type

0

1

1

None

While in machine
setting mode

206

Enabling current limit external input

0

1

0

None

While in machine
setting mode

207

Simplified scaling weighted data

1

64

4

None

While in machine
setting mode

213

Maximum velocity

1

16000000

Motor dependent

Axis command
unit/sec

While in machine
setting mode

218

Enables error when over-load occurs

0

1

1

None

While in machine
setting mode

219

Velocity feedback filter use

0

1

0

None

While in machine
setting mode

220

Velocity feedback filter bandwidth

50

1000

1000

Hz

While in machine
setting mode

221

Velocity command filter bandwidth

50

1000

1000

Hz

While in machine
setting mode

222

Enables error when over-speed occurs

0

1

1

None

While in machine
setting mode

224

Enables error when excessive position
deviation occurs

0

1

1

None

While in machine
setting mode

227

Over-speed error processing type

0

2

1

None

While in machine
setting mode

228

Over-load error processing type

0

2

1

None

While in machine
setting mode

229

Excessive position deviation error
processing type

0

2

1

None

While in machine
setting mode

Advertising