Wiring of Regenerative Alarm Contact <CNA>
(For 500W Level Drive Only)

This driver (with regenerative terminal) is equipped with a regenerative circuit failure detection circuit. When
connecting the regenerative circuit, build a sequence circuit as shown in the figure below in order to prevent
burnout incidents.

Note: Build a sequence circuit so that it will turn off the power supply at alarm operation.

<TB1>

MC

<CNA>

L

N

MC

ON

OFF

MC

Regenerative
alarm
250 V AC 0.1 A
30 V DC 1 A

MC

LINE

Driver

<CNA>

Made by Phoenix Contact
(plug: MC1, 5/2-ST-5, 08)

7 mm

Blade point of the driver used
Thickness 0.4mm, width 2.5mm
(clamping torque: 0.22 to 0.25 [N-m]

Direction of
insertion