7-3

[Multi-channel]

When preparing for multi-channel communication, connect the host device and a maximum of nine drives in a
loop shape as shown in the figure below.

03

02

05

TxD

RxD

SG

03

02
05

TxD

RxD

SG

Driver 1

PC

DOS/V

D-sub 9-pin male

D-sub 9-pin female

PC98

D-sub 25-pin male

09 SG

03

02
05

TxD

RxD

SG

Driver 2

D-sub 9-pin male

09 SG

03

02
05

TxD

RxD

SG

Driver 9

D-sub 9-pin male

09 SG

02

03

07

TxD

RxD

SG

03

02
05

TxD

RxD

SG

Driver 1

PC

D-sub 9-pin male

09 SG

03

02
05

TxD

RxD

SG

Driver 2

D-sub 9-pin male

09 SG

03

02
05

TxD

RxD

SG

Driver 9

D-sub 9-pin male

09 SG

05

04

CTS

RTS

In multi-channel communication, the host device is assigned to host ID “0.” The drivers should be set as slave
stations
and the IDs should be set for each driver from “1” to “9” in such a way that the station numbers do not
overlap, using the rotary switch RS-ID on each driver’s front panel. The order of the IDs does not need to be the
same as the order of connection. This setting should also be made before turning the power on.