Parker Hannifin Dynaserv G2 User Manual

Page 20

Advertising
background image

1-9

[Details of Setting Switches and Status Display LEDs]

SRV-DS Servo disable switch

The servo is turned off for as long as this switch is pressed, regardless
of the command status of the RS232C interface and PLC interface.

When the power is turned on, the operation status of the driver is
determined by the status of these switches.
bit1

Reset all
If this bit is on when the power is turned on, all driver
information is reset to the default status at shipping.

bit2

Reserved

bit3

Reserved

bit4

Maintenance operation setting
If this bit is on when the power is turned on, the driver is set
in maintenance operation status. Normally, this bit should be
set to off.

PSW1

Piano switch

bit1

Test operation

Starts test operation when the lever is up.
Ends test operation when the lever is down.

bit2

RS-232C operation enable

Enables or disables the following
commands from the RS-232C interface
depending on the status when the power is
turned on.
Commands to be disabled: @1 Abort

@2 Stop
@3 Stop
@11 Jog

Lever up:

Enable

Lever down: Disable

CN4

Controller interface connector

Error display LED

Displays an error code when an error occurs.
When resetting:

"0" (lit)

When operating:

"." (flashing)

Check terminal

0

9

8

7

6

5

4

3

2

1

ON

V

V

V

A

B

C

GND

TB1

RS ID

SRV DS

SW1

1

4

MOTOR

GND

LINE

200-

230VAC

RS EN

COIN

ZERO

GND

TEST

- CN4 -

- TB2 -

1

7

- CN3 -

- CN2 -

RS232C

- CN1 -

COIN

AXIS

BUSY

CRDY

SRDY

ERR

RS-ID Rotary switch

SW1 Slide switch

Status display LEDs

CRDY

CPU ready

Indicates that the driver finished its initial
processing and went into its normal status.

SRDY

Servo ready

ERR

Error status

BUSY

Busy

Indicates that the driver is currently
operating.

AXIS

Axis is operating Indicates that the axis is currently operating

(dwell operation)

COIN

Settling status

Indicates that the axis is in its position
settling status.

The communication method of the RS232C interface is set according
to the status of this switch when the power is turned on.
0

Single channel communication

1 to 9

Multi-channel communication. The value corresponds to
the ID of the slave station.

COIN

Settling

Indicates that the axis is in its position settling
status.

ZERO

Zero signal status

(LED display indicates the Zero signal status.)

GND

Digital ground

1

Advertising