5 homing offset position setting @10, 6 jog move command @11: field 0, 7 other convenient commands – Parker Hannifin Dynaserv G2 User Manual

Page 91

Advertising
background image

7-7

7.4.5

Homing offset position setting @10

The homing offset position setting command instructs the #29 Offset distance from the home position
parameter to auto-set so that the current motor position will become the position after homing is completed from
the next time. It functions irrespectively of the operation mode. It can only be run while in the idle status.
When the command is issued, the current command unit command value and the value of the #29 parameter at
that point are added. This value is temporality stored in the #29 parameter.
The response is issued immediately.

7.4.6

Jog move command @11: Field 0

The jog move command is for performing jog operations. This command can be executed in the idle status when
the #217 Jog move operation: RS232C selection parameter is set so that operations are performed via the
RS232C interface.
When field 0 contains “1” a move in the + direction is commanded, when it contains “-1” a move in the -
direction is commanded, and when it contains “0,” a stop command is issued.
In the idle status, a jog move is performed as commanded by this command. If a start command is issued during
a jog move, the move is immediately decelerated and stopped, after which the operation is started. If the
operation is ended after that, the motor remains stopped regardless of the jog move status before starting the
operation.
The response is issued immediately.

7.4.7

Other convenient commands

Command name

Command No.

Number of fields

Response at

normal operation

Status request

0

1

R3H

Software driver reset

96

0

None

[Status request] @0:0

This command notifies the status of the driver. It functions irrespectively of the operation mode. The response is
issued immediately.

Response character string: R3H:driver status:execution program number:execution block number

Driver status

Value

Bit No.

Content

0

1

0

Operation mode

PLC

RS232C

1

Servo ready

Not ready

Ready

2

Operation is being executed

Not being executed

Being executed

3

Axis operation is being executed

Not being executed

Being executed

9

Mechanical setting mode is
being executed

Not being executed

Being executed

16

Error status

Not in error status

Error status

17

Alarm status

Not in alarm status

Alarm status

Others

(Reserved)

[Software driver reset] @96

This command is software equivalent to turning the power to the driver off and on.
There is no response.

7