2 cable specification list – Parker Hannifin Dynaserv G2 User Manual

Page 27

Advertising
background image

3-3

3.2

Cable Specification List

Cable name

Electric cable size

Driver

Current (A)

1)

AC power supply
cable

2.0 mm

2

or more, 30 m or less in length

TB1

*

2)

Ground cable (power
supply)

2.0 mm

2

or more

TB1

*

3)

Motor cable

2.0 mm

2

or more, 30 m or less in length

TB1

*

4)

Sensor brake cable

0.3 to 0.75 mm

2

TB2

5)

RS232C
communication cable

Dedicated cable is required.

CN1

6)

Encoder resolver
cable

0.2mm

2

twisted pair, batch shielded cable, outer

diameter

φ 14 mm or less, 10 m or less in length

CN2

Maximum
100 mA DC

7)

Jumper cable

2.0 mm

2

or more

TB1

*

8)

Analog monitor card

Dedicated cable is required. [R7033YB] (cable
with connector)

CN3

9)

Controller cable

0.2 to 0.5mm

2

, batch shielded cable, outer

diameter

φ 9 mm or less, 3 m or less in length

CN4

Maximum
500 mA DC

*

20A for the A (

φ 264mm) and E (φ 205mm) types for both the DM and DR series

15A for the B (

φ 160mm) type, and 10A for the DM1004B/1004C motors

3