390

Motor linear coordinate command differential value

Unit:

pulse/

∆T

Displays the differential value of the motor linear coordinate command value. (2msec sample)

391

Present motor linear coordinate differential value

Unit:

pulse/

∆T

Displays the differential value of the present motor linear coordinate value. (2msec sample)

392

Pre-filter current square duty

Unit:

digit

Displays the pre-filter current square duty (decimal point 15 bits).

393

Post-filter current square duty

Unit:

digit

Displays the post-filter current square duty (decimal point 15 bits)

396

Driver code

Unit:

None

Displays the driver code.

398

Motor code

Unit:

None

Displays the motor code.

399

Time after power ON [msec]

Unit:

msec

Indicates the time after the power has been turned on.