Installation of the Driver

The standard installation method for the driver is either to mount it on a rack or a wall.

(1) Installation Position

! If there is a heating source near by, the temperature should be prevented from increasing by installing a

shielding cover, etc.; the temperature around the driver should not exceed 50

°C (Note 1).

! If there is a source of vibration near by, the rack should be installed via a vibration absorption material.
! In addition to the above, it should be avoided to install the driver in surroundings that are high in

temperature and humidity, filled with dust, metal powder, corrosive gas, etc.

(2) Installation Method

! The standard way of installation is to install the driver on a rack, aligning the top and bottom with the

front panel in the front. Do not put the panel surface into a sideways position or upside down (see the
figure below).

! The driver box employs a natural air ventilation system. Make sure to secure space for ventilation above

and below (25 mm or more) and right and left (25 mm or more) (see the figure below).

! Make sure to use the installation holes (four places) of the upper and lower brackets at installation.

25 mm

25 mm

Should not be installed in a

sideways position.

Should not be
installed
upside down.

(Note: 1)

2 kW level drivers, but not other types, will have the current characteristics shown in the graph below as a
function of the ambient air temperature during operation. Therefore, it is recommended to use the driver in an
ambient air temperature of 40

°C or less in order to prolong its life.

0%

Ambient air temperature during operation

Square current duty

40℃

50℃

60℃

Current derating curve

10%

20%

30%

40%

50%

25%

45%

10℃

20℃

30℃

0℃