Parker Hannifin Dynaserv G2 User Manual

Page 61

Advertising
background image

5-7

[Hardware zero signal type]

318 value

0.05*#358 value

error

0.05*#358 value

318 value

0.1 *#358 value

warning

0.1 *#358 value

318 value

0.7 *#358 value

normal

0.7 *#358 value

318 value

0.75*#358 value

warning

0.75*#358 value

318 value

error

[Software zero signal type]

318 value

0.05*#358 value

error

0.05*#358 value

318 value

0.1 *#358 value

warning

0.1 *#358 value

318 value

0.4 *#358 value

normal

0.4 *#358 value

318 value

0.45*#358 value

warning

0.45*#358 value

318 value

error

5

Advertising