Rs232c interfaces, 1 overview, 2 connection and setting – Parker Hannifin Dynaserv G2 User Manual

Page 86

Advertising
background image

7-2

RS232C Interfaces

7

7.1

Overview

The CN1 RS232C communication connector is provided in order to make connection with host devices such as
PCs and PLCs via the RS232C. The operation display pendant (abbreviated as TBX, optional device) can also
be connected to this connector. Refer to Chapter 9, “Operation Display Pendant” for a description of how to use
the operation display pendant. This chapter explains how to connect the CN1 RS232C communication connector
to devices other than the operation display pendant.
In the RS232C interface, two communication modes are available. The first is a single channel
communication
where the connection is made 1:1 with the host device, and the other is a multi-channel
communication
where 1:N communication can be performed by connecting one host device with several of
these drivers (a maximum of nine). Please note that the connection and operation methods are different for each
communication mode.
In addition, the PC utility (optional) running under Windows can also be connected to the drivers via the
RS232C interface in order to support setting, operation, and maintenance work on the drivers. Refer to Chapter 8,
“DrvGII PC Utility” for a description of how to use the PC utility.

7.2

Connection and Setting

[Connectors and terminal assignment]

01

FG

06

05

04

03

02

SG

(NC)

TxD

RxD

09

08

07

XTBXON

XTBXEMG

+5V

Do not use these connections,
since they are used for the
operation display pendant.

Made by Japan Aviation Electronics
DELC-J9SAF13L6 (9 pins)

SG

[Single channel]

The connection cables (optional) are available according to the PC to be connected (DOS/V, NEC PC98).

02

09

03

05

RxD

SG

TxD

SG

02

03
05

RxD

TxD

SG

Driver

PC

DOS/V

D-sub 9-pin male

D-sub 9-pin female

02

09

03

05

RxD

SG

TxD

SG

03

02
07

RxD

TxD

SG

Driver

PC

PC98

D-sub 9-pin male

D-sub 25-pin male

05

04

CTS

RTS

Option cable
CP7576S-020 (2 m)

Option cable
CP7577S-020 (2 m)

In order to set the communication mode to the single channel mode, the rotary switch RS-ID on the front panel
should be turned to “0.” This setting should be made before turning the power on.

Advertising