6 wiring of controller cable – Parker Hannifin Dynaserv G2 User Manual

Page 33

Advertising
background image

3-9

3.6

Wiring of Controller Cable

<CN4> terminal

Pin #

Signal name

Pin #

Signal name

Pin #

Signal name

Pin #

Signal name

1 COMP1

10 UA_OUT-

19 IN_ERR_RESET

28 IN_FN

2 COMN1

11 DB_OUT+

20 IN_SERVO

29 IN_PLS_DIRECT

3 OUT_DRDY

12 DB_OUT-

21 IN_MODE_START

30 IN_PACT

4 OUT_SRDY

13 Z_OUT+

22 IN_ABORT

31 (NC)

5 OUT_BUSY

14 Z_OUT-

23 IN_MODE.0

32 (NC)

6 OUT_XOVL

15 PUA_IN+

24 IN_MODE.1

33 CRNT_LMT_IN+

7 OUT_OVER

16 PUA_IN-

25 IN_POSW.0

34 CRNT_LMT_IN-

8 OUT_COIN

17 SDB_IN+

26 IN_POSW.1

35 (NC)

9 UA_OUT+

18 SDB_IN-

27 IN_GAIN

36 (NC)

Electric wire
specification

!

0.2 to 0.5 mm2 or more, multiple-core batch shielded cable, 3 m or
less in length

!

Optional cable: CP4202G-"""

19

36

18

1

3

2

1

18

36

21

20

19

Insertion surface

Chassis ground

(shielded cable)

Soldering surface

Terminal for <CN4>
Made by Honda Tsushin Kogyo
Connector: PCR-S36FS
Housing: PCR-LS36LA

3