361

Velocity ratio gain

Unit:

x 1/100

Displays the velocity loop ratio gain.

363

Velocity command value (digital)

Unit:

1/16 digit

Displays the velocity command value when controlling the digital velocity. (1msec sample)

364

Post-filter velocity command value (digital)

Unit:

1/16 digit

Displays the post-filter velocity command value when controlling the digital velocity. (1msec sample)

365

Present velocity current value

Unit:

1/16 digit

Displays the present velocity value. (1msec sample)

366

Present post-filter velocity value

Unit:

1/16 digit

Displays the present post-filter velocity value. (1msec sample)

367

Velocity deviation (digital)

Unit:

1/16 digit

Displays the velocity deviation. (1msec sample)

368

Current command value (D/A)

Unit:

digit

Displays the current command value D/A output value. The conversion rate is as follows:

1 digit = 0.0036%

27853 digits:

+100%

0 digits:

0%

-27853 digits:

-100%

369

Present current value (A/D)

Unit:

digit

Displays the A/D input value of the present current command value.(1msec sample) The conversion rate is as follows:

1 digit = 0.0036%

27840digits:

+100%

0 digits:

0%

-27840 digits:

-100%