Parker Hannifin Dynaserv G2 User Manual

Page 161

Advertising
background image

73

Position monitoring gain (analog monitor)

Always

Minimum value: 0
Maximum value: 14
Initial value:

0

Unit:

None

Long:

Short:

PosMonitorGain

PosMon_G

Specify the position monitoring (position command value and current position value) gain of the analog monitor.

0: 6.55V / 4194304 pulses
1: 6.55V / 2097152 pulses
2: 6.55V / 1048576 pulses
3: 6.55V / 524288 pulses
4: 6.55V / 262144 pulses
5: 6.55V / 131072 pulses
6: 6.55V / 65536 pulses
7: 6.55V / 32768 pulses
8: 6.55V / 16384 pulses
9: 6.55V / 8192 pulses
10: 6.55V / 4096 pulses
11: 6.55V / 1024 pulses
12: 6.55V / 512 pulses
13: 6.55V / 256 pulses
14: 6.55V/ 128 pulses

74

Position differential value monitoring gain (analog
monitor)

Always

Minimum value: 0
Maximum value: 7
Initial value:

0

Unit:

None

Long:

Short:

VelMonitorGain

VelMon_G

Specify the position differential value monitoring (position command differential value and current position differential
value) gain of the analog monitor.

0: 6.55V / 8192000 pulses
1: 6.55V / 4096000 pulses
2: 6.55V / 2048000 pulses
3: 6.55V / 1024000 pulses
4: 6.55V / 512000 pulses
5: 6.55V / 256000 pulses
6: 6.55V / 128000 pulses
7: 6.55V / 64000 pulses

75

Velocity monitor selection (digital monitor)

Always

Minimum value: 0
Maximum value: 1
Initial value:

0

Unit:

None

Long:

Short:

VelMonSel(Digital)

VelMonSelD

This parameter switches the velocity monitoring output content when controlling the digital velocity.

0: Velocity monitor
1: Velocity monitor AC

89

Brake turn OFF delay time upon Servo ON

Always

Minimum value: 0
Maximum value: 2000
Initial value:

0

Unit:

msec

Long:

Short:

TimeSrvOn_toBrkOff

TimeBrkOff

Specify the delay time from servo ON to brake OFF.

90

Advanced Brake turn ON before Servo OFF

Always

Minimum value: 0
Maximum value: 000
Initial value:

0

Unit:

msec

Long:

Short:

TimeBrkOn_toSrvOff

TimeBrkOn

Specify the advanced time for brake ON before servo OFF.

Advertising