Example: To generate 1/4 duty 62.5 kHz pulses (at f

C

= 40 MHz):




Calculate the value that should be set in the timer register.

To obtain a frequency of 62.5 kHz, the pulse cycle t should be: t = 1/62.5 kHz = 16

μs

φT1 (= (16/fc)s (at f

C

= 40MHz);

16

μs/(16/fc)s = 40

Therefore set TA1REG to 40 (28H)

The duty is to be set to 1/4: t

× 1/4 = 16 μs × 1/4 = 4 μs

4

μs/(16/fc)s = 10

Therefore, set TA0REG

= 10 = 0AH

7

6

5

4

3

2

1

0

TA01RUN

← 0 X X X − 0

0

0

Stop TMRA0 and TMRA1 and clear it to “0”.

TA01MOD

← 1 0 X X X X 0

1

Set the 8-bit PPG mode, and select

φT1 as input clock.

TA0REG

← 0

0

0

0

1

0

1

0

Write 0AH.

TA1REG

← 0

0

1

0

1

0

0

0

Write 28H.

TA1FFCR

← X X X X 0

1

1

X

Set TA1FF and set inversion to enable.
Writing “10” provides negative logic pulse.

PCCR

← X

− −

X

X

1

PCFC

← X

− −

X

X

1

Set PC1 to TA1OUT pin.

TA01RUN

← 1 X X X

1

1

1

Start TMRA0 and TMRA1 counting.

X

: Don’t care, − : No change

16

μs

Advertising
This manual is related to the following products: