Toshiba H1 SERIES TLCS-900 User Manual

Page 170

Advertising
background image

TMP92CM22

2007-02-16

92CM22-168

Example: To link two slave controllers serially with the master controller using the system

clock f

IO

as the transfer clock.

• Master controller setting

Main routine

PFCR

← − − − − − − 0 1

PFFC

← − − − − − − X 1

Set PF0 to TXD0, and set PF1 to RXD0 pin.

INTES0

← 1 1 0 0 1 1 0 1

Set INTTX0 to enable, and set interrupt level to level 4.

Set INTRX0 to enable, and set interrupt level to level 5.

SC0MOD0

← 1 0 1 0 1 1 1 0

Set to 9-bit UART mode, and set transfer clock to f

IO.

SC0BUF

← 0 0 0 0 0 0 0 1

Set

select

code

of

slave

1.

Interrupt routine (INTTX0)

SC0MOD0

← 0 − − − − − − −

Set TB8 to “0”.

SC0BUF

← ∗ ∗ ∗ ∗ ∗ ∗ ∗ ∗ Set

transmission

data.

• Slave setting

Main routine

PFCR

← − − − − − − 0 0

PFFC

← − − − − − − X 1

Set PF0 to TXD (open-drain output), and PC1 to RXD.

INTES0

← 1 1 0 1 1 1 1 0

Set INTTX0 and INTRX0 to enable.

SC0MOD0

← 0 0 1 1 1 1 1 0

Set to <WU>

= “1” in 9-bit UART mode transfer clock f

IO.

Interrupt routine (INTRX0)

Acc

← SC0BUF

if Acc

= Select code

Then
SC0MOD0

← − − − 0 − − − −

Clear to <WU>

= “0”.

TXD

RXD


Master

TXD

RXD


Slave 1

TXD

RXD


Slave 2

Select code

00000001

Select code

00001010

Advertising