TMP92CM22

2007-02-16

92CM22-178

3.10.5 Control in I

2

C Bus Mode

(1) Acknowledge mode specification

Set the SBI0CR1<ACK> to 1 for operation in the acknowledge mode. The

TMP92CM22 generates an additional clock pulse for an acknowledge signal when
operating in master mode. In the transmitter mode during the clock pulse cycle, the
SDA pin is released in order to receive the acknowledge signal from the receiver. In the
receiver mode during the clock pulse cycle, the SDA pin is set to the low in order to
generate the acknowledge signal.

Clear the <ACK> to 0 for operation in the non-acknowledge mode, the TMP92CM22

does not generate a clock pulse for the acknowledge signal when operating in the
master mode.

(2) Select number of transfer bits

The SBI0CR1<BC2:0> is used to select a number of bits for next transmission/

receiving data.

Since the <BC2:0> is cleared to 000 as a start condition, a slave address and

direction bit are transferred in 8 bits. Other than these, the <BC2:0> retains a
specified value.

(3) Serial clock

1. Clock

source

The SBI0CR1<SCK2:0> is used to select a maximum transfer frequency outputted

on the SCL pin in master mode. Set the baud rates, which have been calculated
according to the formula below, to meet the specifications of the I

2

C bus, such as the

smallest pulse width of t

LOW

.

SBI0CR1<SCK2:0> n

000 5

001 6

010 7

011 8

100 9

101 10

110 11

Note: f

SBI

shows f

SYS

.

Figure 3.10.7 Clock Source

t

HIGH

t

LOW

1/fscl

t

LOW

= 2

n

− 1

/f

SBI

t

HIGH

= 2

n

− 1

/f

SBI

+ 8/f

SBI

fscl

= 1/(t

LOW

+ t

HIGH

)

f

SBI

2

n

+ 8

=

Advertising