Toshiba H1 SERIES TLCS-900 User Manual

Page 57

Advertising
background image

TMP92CM22

2007-02-16

92CM22-55

Port 4 Register

7 6 5 4 3 2 1 0

Bit

symbol

P47 P46 P45 P44 P43 P42 P41 P40

Read/Write R/W

After reset

Data from external port (Output latch register is cleared to “0”.)

Port 4 Control Register

7 6 5 4 3 2 1 0

Bit

symbol P47C P46C P45C P44C P43C P42C P41C P40C

Read/Write W

After

reset

0 0 0 0 0 0 0 0

Function

0: Input 1: Output (Note2)

Port 4 Function Register

7 6 5 4 3 2 1 0

Bit

symbol P47F P46F P45F P44F P43F P42F P41F P40F

Read/Write W

After

reset

1 1 1 1 1 1 1 1

Function

0: Port 1: Address bus (A0 to A7)

Note1: Read-modify-write instruction is prohibited for registers P4CR and P4FC.

Note2: When these ports are used as general-purpose I/O port, each bit can be set individually for input or output.

However, each bit cannot be set individually for input or output even if 1bit or more bits are used as address

bus in same port. All of general-purpose I/O ports except for port that used as address bus are operated as

output port. Please be careful when using this setting.

Figure 3.5.4 Register for Port 4

P4

(0010H)

P4CR

(0012H)

P4FC

(0013H)

Advertising
This manual is related to the following products: