Toshiba H1 SERIES TLCS-900 User Manual

Page 172

Advertising
background image

TMP92CM22

2007-02-16

92CM22-170

(3) Data format

Format of transmission/receiving must set to data length 8-bit, without parity bit, 1 bit
of stop bit.

Any other settings don’t guarantee the normal operation.

(4) SFR

Figure 3.9.27 shows the control register SIRCR. If change setting this register, must

set it after set operation of transmission/receiving to disable (Both <TXEN> and
<RXEN> of this register should be clear to 0).

Any changing for this register during transmission or receiving operation doesn’t

guarantee the normal operation.

The following example describes how to set this register:

1) SIO setting

; Set SIO side.

2) LD (SIRCR), 07H

; Set receiving effect pulse width to 16X.

3) LD (SIRCR), 37H

; TXEN, RXEN enable the transmission and receiving.

4) Transmission/receiving ; The modem operates as follows:

• SIO0 starts transmitting.
• IR receiver starts receiving.

(5) Notes

1. Making baud rate when using IrDA

In baud rate during using IrDA, must set “01” to SC0MOD0<SC1:0> in SIO by

using baud rate generator.

TA0TRG, f

IO

, SCLK0 input of except for it can not using.

2. Output pulse width and baud rate generator during transmission IrDA

As the IrDA 1.0 physical layer specification, the data transfer speed and

infra-red pulse width is specified.

Table 3.9.4 Specification of Transfer Rate and Pulse Width

Transfer

Rate

Modulation

Transfer Rate

Tolerance

(% of Rate)

Minimum of

Pulse Width

Typical of Pulse

Width 3/16

Maximum of

Pulse Width

2.4 kbps

RZI

± 0.87

1.41

μs 78.13

μs 88.55

μs

9.6 kbps

RZI

± 0.87

1.41

μs 19.53

μs 22.13

μs

19.2 kbps

RZI

± 0.87

1.41

μs 9.77

μs 11.07

μs

38.4 kbps

RZI

± 0.87

1.41

μs 4.88

μs 5.96

μs

57.6 kbps

RZI

± 0.87

1.41

μs 3.26

μs 4.34

μs

115.2 kbps

RZI

± 0.87

1.41

μs 1.63

μs 2.23

μs

The infra-red pulse width is specified either baud rate T

× 3/16 or 1.6 μs (1.6 μs is

equal to T

× 3/16 pulse width when baud rate is 115.2 kbps).

The TMP92CM22 has function which is selectable the transmission pulse width

either 3/16 or 1/16. But T

× 1/16 pulse width can be selected when the baud rate is

equal or less than 38.4 kbps only. When 57.6 kbps and 115.2 kbps, the output pulse
width should not be set to T

Ч 1/16.