Toshiba H1 SERIES TLCS-900 User Manual

Page 203

Advertising
background image

TMP92CM22

2007-02-16

92CM22-201

AD Mode Control Register 1

7 6 5 4 3 2 1 0

Bit symbol

VREFON

I2AD

− ADCH2

ADCH1

ADCH0

ADMOD1
(12B9H)

Read/Write R/W

After

reset

0 0 0 0 0 0 0 0

Function

VREF
application
control

0: OFF

1: ON

IDLE2

0: Stop

1: Operate

Always
write “0”.

Always write
“0”.

Always
write “0”.

Analog input channel selection

<SCAN>

<ADCH2:0>

0

Channel

fixed

1

Channel

scanned

000

AN0

AN0

001

AN1

AN0

→ AN1

010

AN2

AN0

→ AN1 → AN2

011 (Note)

AN3

AN0

→ AN1 → AN2 → AN3

100 (Note)

AN4

AN0

→ AN1 → AN2 → AN3

→ AN4

101 (Note)

AN5

AN0

→ AN1 → AN2 → AN3

→ AN4 → AN5

110 (Note)

AN6

AN0

→ AN1 → AN2 → AN3

→ AN4 → AN5 → AN6

111 (Note)

AN7

AN0

→ AN1 → AN2 → AN3

→ AN4 → AN5 → AN6 → AN7

0

Stopped

1

In operation

0

OFF

1

ON

AD Mode Control Register 2

7 6 5 4 3 2 1 0

Bit symbol

ADTRGE

ADMOD2
(12BAH)

Read/Write

R/W

After

reset

0

Function

AD conversion

trigger start

control

0: Disable

1. Enable

0

Disabled

1

Enabled

Note:

As pin AN3 also functions as the

ADTRG

input pin, do not set <ADCH2:0> = “011, 100,101,110,111” when

using

ADTRG

with <ADTRGE> set to “1”.

Figure 3.11.3 Register for AD Converter

IDLE2 control

Control of application of reference voltage
to AD converter

Before starting conversion (before writing 1
to ADMOD0<ADS>), set the <VREFON> bit
to 1.

AD conversion start control by external
trigger (

ADTRG

input )

Analog input channel selection

Advertising