Toshiba H1 SERIES TLCS-900 User Manual

Page 149

Advertising
background image

TMP92CM22

2007-02-16

92CM22-147

• Integer divider (N divider)

For example, when the f

C

= 39.3216 MHz, the input clock frequency = φT2, the

frequency divider N (BR0CR<BR0S3:0>)

= 8, and BR0CR<BR0ADDE> = 0, the

baud rate in UART mode is as follows:

∗ Clock state

Clock gear:

1/1 (f

C

)

f

C

/32

8

= 39.3216 Ч 10

6

ч 16 ч 8 ч 16 = 9600 (bps)

Note: The

N

+ (16 − K)/16 division function is disabled and setting BR0ADD<BR0K3:0>

is invalid.

• N + (16 − K)/16 divider (UART mode only)

Accordingly, when f

C

= 31.9488 MHz, the input clock frequency = φT2, the

frequency divider N (BR0CR<BR0S3:0>)

= 6, K (BR0ADD<BR0K3:0>) = 8, and

BR0CR<BR0ADDE>

= 1, the baud rate is as follows:

* Clock state

Clock gear:

1/1 (f

C

)

f

C

/32

(16

− 8)

16

= 31.9488 Ч 10

6

ч 32 ч (6 + ) ч 16 = 9600 (bps)

Table 3.9.3 show examples of UART mode transfer rates.
Additionally, the external clock input is available in the serial clock (Serial

channels 0 and 1). The method for calculating the baud rate is explained below:

• In UART mode

Baud rate

= External clock input frequency ÷ 16

It is necessary to satisfy (External clock input cycle)

≥ 4/f

SYS

• In I/O interface mode

Baud rate

= External clock input frequency

It is necessary to satisfy (External clock input cycle)

≥ 16/f

SYS


Baud rate

=

ч

16

8

16

ч 16

6

+

Baud rate

=

Advertising