2 description of operation – Toshiba H1 SERIES TLCS-900 User Manual

Page 208

Advertising
background image

TMP92CM22

2007-02-16

92CM22-206

3.11.2 Description

of

Operation

(1) Analog reference voltage

A high-level analog reference voltage is applied to the VREFH pin; a low-level analog

reference voltage is applied to the VREFL pin. To perform AD conversion, the reference
voltage, the difference between VREFH and VREFL, is divided by 1024 using string
resistance. The result of the division is then compared with the analog input voltage.

To turn off the switch between VREFH and VREFL, program a 0 to

ADMOD1<VREFON> in AD mode control register 1. To start AD conversion in the
OFF state, first write a 1 to ADMOD1<VREFON>, wait 3

μs until the internal

reference voltage stabilizes (This is not related to f

SYS

), then set ADMOD0<ADS> to 1.

(2) Analog input channel selection

The analog input channel selection varies depends on the operation mode of the AD

converter.

• In analog input channel fixed mode (ADMOD0<SCAN> = 0)

Setting ADMOD1<ADCH2:0> selects one of the input pins AN0 to AN7 as the input
channel.

• In analog input channel scan mode (ADMOD0<SCAN> = 1)

Setting ADMOD1<ADCH2:0> selects one of the eight scan modes.

Table 3.11.1 illustrates analog input channel selection in each operation mode.
On a reset, ADMOD0<SCAN> is set to “0” and ADMOD1<ADCH2:0> is initialized to

“000”. Thus pin AN0 is selected as the fixed input channel. Pins not used as analog
input channels can be used as standard input port pins.

Table 3.11.1 Analog Input Channel Selection

<ADCH2:0>

Channel fixed

<SCAN>

= “0”

Channel scan

<SCAN>

= “1”

000 AN0

AN0

001 AN1

AN0

→ AN1

010 AN2

AN0

→ AN1 → AN2

011 AN3

AN0

→ AN1 → AN2 → AN3

100 AN4

AN0

→ AN1 → AN2 → AN3

→ AN4

101 AN5

AN0

→ AN1 → AN2 → AN3

→ AN4 → AN5

110 AN6

AN0

→ AN1 → AN2 → AN3

→ AN4 → AN5 → AN6

111 AN7

AN0

→ AN1 → AN2 → AN3

→ AN4 → AN5 → AN6 → AN7

Advertising
This manual is related to the following products: