Toshiba H1 SERIES TLCS-900 User Manual

Page 152

Advertising
background image

TMP92CM22

2007-02-16

92CM22-150

(6) The receiving buffers

To prevent overrun errors, the receiving buffers are arranged in a double-buffer

structure.

Received data is stored one bit at a time in receiving buffer 1 (which is a shift

register). When 7 or 8 bits of data have been stored in receiving buffer 1, the stored
data is transferred to receiving buffer 2 (SC0BUF); this causes an INTRX0 interrupt to
be generated.

The CPU only reads receiving buffer 2 (SC0BUF). Even before the CPU reads

receiving buffer 2 (SC0BUF), the received data can be stored in receiving buffer 1.

However, unless receiving buffer 2 (SC0BUF) is read before all bits of the next data

are received by receiving buffer 1, an overrun error occurs. If an overrun error occurs,
the contents of receiving buffer 1 will be lost, although the contents of receiving buffer
2 and SC0CR<RB8> will be preserved.

SC0CR<RB8> is used to store either the parity bit – added in 8-bit UART mode – or

the most significant bit (MSB) – in 9-bit UART mode.

In 9-bit UART mode the wake-up function for the slave controller is enabled by

setting SC0MOD0<WU> to 1; in this mode INTRX0 interrupts occur only when the
value of SC0CR<RB8> is 1.

(7) Transmission counter

The transmission counter is a 4-bit binary counter that is used in UART mode and

which, like the receiving counter, counts the SIOCLK clock pulses; a TXDCLK pulse is
generated every 16 SIOCLK clock pulses.

Figure 3.9.4 Generation of Transmission Clock

(8) Transmission controller

• In I/O interface mode

In SCLK output mode with the setting SC0CR<IOC>

= 0, the data in the

transmission buffer is output one bit at a time to the TXD0 pin on the rising or
falling edge of the shift clock which is output on the SCLK0 pin, according to the
SC0CR<SCLKS> setting.

In SCLK input mode with the setting SC0CR<IOC>

= 1, the data in the

transmission buffer is output one bit at a time on the TXD0 pin on the rising or
falling edge of the SCLK0 input, according to the SC0CR<SCLKS> setting.

• In UART mode

When transmission data sent from the CPU is written to the transmission buffer,

transmission starts on the rising edge of the next TXDCLK, generating a
transmission shift clock TXDSFT.

15

16 1 2 3 4 5

6

7

8

9

10

11

12

13

14

15

16 1 2

SIOCLK

TXDCLK

Advertising