1 analog/digital converter registers – Toshiba H1 SERIES TLCS-900 User Manual

Page 202

Advertising
background image

TMP92CM22

2007-02-16

92CM22-200

3.11.1 Analog/Digital Converter Registers

The AD converter is controlled by the three AD mode control registers: ADMOD0,

ADMOD1, and ADMOD2. The eight AD conversion data result registers (ADREG0H/L to
ADREG7H/L) store the results of AD conversion.

Figure 3.11.2 shows the registers related to the AD converter.

AD Mode Control Register 0

7 6 5 4 3 2 1 0

Bit symbol

EOCF

ADBF

− ITM0

REPEAT

SCAN

ADS

ADMOD0
(12B8H)

Read/Write R

R/W

After

reset

0 0 0 0 0 0 0 0

Function

AD
conversion
end flag

0: Conversion
in

progress

1: Conversion

complete

AD
conversion
busy flag

0: Conversion

stopped

1: Conversion

in

progress

Always
write “0”.

Always
write “0”.

Interrupt
specification
in
conversion
channel
fixed repeat
mode

0: Every
conversion

1: Every

fourth

conversion

Repeat
mode
specification

0: Single

conversion

1: Repeat

conversion

mode

Scan mode
specification

0: Conversion
channel
fixed

mode

1: Conversion

channel

scan

mode

AD
conversion
start

0: Don’t care
1: Start

conversion

Always 0 when

read.

0

Don’t care

1

Start AD conversion.

0

AD conversion channel fixed mode

1

AD conversion channel scan mode

0

AD single conversion mode

1

AD repeat conversion mode

Channel fixed repeat conversion mode
<SCAN>

= “0”, <REPEAT> = “1”

0

Generates interrupt every conversion.

1

Generates interrupt every fourth
conversion.

0

AD conversion stopped

1

AD conversion in progress

0

Before or during AD conversion

1

AD conversion complete

Figure 3.11.2 Register for AD Converter

AD conversion start

AD scan mode setting

AD repeat mode setting

Specify AD conversion interrupt for
channel fixed repeat conversion mode

AD conversion busy flag

Note: Always read as 0.

AD conversion in progress

Advertising
This manual is related to the following products: