TMP92CM22

2007-02-16

92CM22-141

3.9

Serial Channels (SIO)

The TMP92CM22 includes 2 serial I/O channels. Each channel is called SIO0 and SIO1. For

both channels either UART Mode (Asynchronous transmission) or I/O interface mode
(Synchronous transmission) can be selected.

• I/O

interface

mode

Mode 0

: For transmitting and receiving I/O data using the

synchronizing signal SCLK for extending I/O.

Mode 1

: 7-bit data

• UART

mode

Mode 2

: 8-bit data

Mode 3

: 9-bit data

In mode 1 and mode 2 a parity bit can be added. Mode 3 has a wakeup function for making the

master controller start slave controllers via a serial link (Multi-controller system).

Figure 3.9.2 and Figure 3.9.3 are block diagrams for each channel. Each channel is

structured in prescaler, serial clock generation circuit, receiving buffer and control circuit, and
transfer buffer and control circuit.

Serial channels 0 and 1 can be used independently.
Both channels operate in the same function except for the following points; hence only the

operation of channel 0 is explained below.

Table 3.9.1 Differences between Channels 0 to 1

Channel 0

Channel 1

Pin name

TXD0 (PF0)

RXD0 (PF1)

CTS0

/SCLK0 (PF2)

TXD1 (PF3)

RXD1 (PF4)

CTS1

/SCLK1 (PF5)

IrDA mode

Yes

No

This chapter contains the following sections:

3.9.1 Block Diagram
3.9.2 Operation of Each Circuit
3.9.3 SFRs
3.9.4 Operation in Each Mode