TMP92CM22

2007-02-16

92CM22-223

4.3

AD Conversion Characteristics

Parameter Symbol

Min

Typ.

Max

Unit

Analog reference voltage (

+) V

REFH

VCC

− 0.2

VCC VCC

Analog reference voltage (

−) V

REFL

VSS

VSS

VSS

+ 0.2

AD converter power supply voltage

A

VCC

VCC

VCC

VCC

AD converter power supply ground

A

VSS

VSS

VSS

VSS

Analog input voltage

A

VIN

VREFL

VREFH

V

Analog current for analog reference voltage

<VREFON>

= 1

I

REF

1.0

1.2

mA

Analog current for analog reference voltage

<VREFON>

= 0

0.02

5.0

UA

Total error

(Include quantize error of

± 0.5 LSB )

E

T

±1.0

±4.0 LSB

4.4

Event Counter (TA0IN, TB1IN0, and TB1IN1)

Variable

f

SYS

=

20 MHz

(fc

= 40 MHz)

f

SYS

=

125 kHz

(fc

= 4 MHz)

Parameter Symbol

MIN MAX

MIN

MAX

MIN

MAX

Unit

Clock cycle

T

VCK

8X

+

100

500 64100 ns

Low-level clock width

T

VCKL

4X

+

40

240 32040 ns

High-level clock width

T

VCKH

4X

+

40

240 32040 ns

Note: Symbol “x” in the above table means the period of clock “f

SYS

”, it’s same period of the system clock “f

SYS

” for

CPU core. The period of f

SYS

depends on the clock gear setting or changing high-speed oscillator/low-speed

oscillator and so on.